PCB BENCH SCALE


EXPERIMENTAL PARAMETERS

500 mls of subsubsurface storage tank water and slurry from a State Superfund Site, temperature adjusted to 70 degrees and pH adjusted to 2.5. Five minute treatment with 840 ppm of 30% H2O2 and 500 mA of current.

PCB PILOT SCALE

EXPERIMENTAL PARAMETERS

Two 200 L samples of subsurface storage tank water from a State Superfund Site at ambient temperature with the pH adjusted to 2. Five minute treatment with 87.5 ppm of 50% H2O2 and 20 amps of current on each.